- Free Shipping on Orders $1,000+
- info@divervision.com
- New Arrivals New
- Packages Hot
-
Underwater Housings
Related
Setup Housing Package
-
Ports
-
Lighting & Accessories
Flashlights
-
Wet Lens by Mounts
Lens Mounts & Holders
-
Arm Control System
Related Products
- Home
- Housings
- INON X-2 R6 Mark II Housing for Canon EOS R6 Mark II INON X-2 R6 Mark II Housing for Canon EOS R6 Mark II
INON X-2 R6 Mark II Housing for Canon EOS R6 Mark II
- Built-in TTL Converter for INON strobes
- 12 shots/sec. continuous shooting
- Built-in Vacuum Leak Sensor
- Description
- Specifications
- Exterior
- A housing for Canon EOS R6 Mark II
- INON strobe compatible ultra-accurate multi-functional built-in "TTL Converter" as standard feature
- Control flash amount directly from camera
- 12 shots/sec. continuous shooting supported
- Standard “Vacuum Leak Sensor (PAT. P)" checks housing sealing in only 5 minutes
- MRS port further evolves to support fine manual focusing
- Optionally available "Quick Shoe System" for quick camera position switching between landscape and portrait composition
- Optional two viewfinders provide bright and clear finder image
- Lightweight and compact ultra-precision cast aluminum body
Ultra-accurate multi-functional built-in TTL Converter
The "TTL Converter" equipped as a standard feature, triggers INON strobe optically to enjoy fully automatic TTL. Exclusively developed for INON strobe based on its flash protocol to optimize its performance for underwater use. As an underwater strobe manufacturer, we successfully achieved the TTL Converter that provides constant, stable and highly accurate TTL exposure. Following parameters can be controlled in the [External Speedlite control] menu of the EOS R6 Mark II.
*When selecting [Enable], shutter speed is limited up to 1/250sec. regardless of INON strobe power setting. When not using a strobe, set to [Disable] not to have the limitation. ** [Flash priority] is recommended in strong ambient light. *** Manual flashing without pre-flash. Recommended to shoot shy subjects not to scare them with pre-flash. ****Set to [M] when shooting in Manual flash mode on INON strobe at [Second-curtain synchronization]. INON strobe is not in synch when the flash mode is set to [E-TTL] and shutter speed is set to 1/8sec. or slower. |
Strobe manual power is directly adjustable from camera
INON strobe manual power is directly adjustable from camera ranging between 1/64 and FULL at 1/3EV. increments. Useful when strobe is positioned away like on long strobe arm or when shooting with backlit technique.
12 shots/sec. continuous strobe firing
The TTL Converter fully supports [High speed continuous][High speed continuous+]. With ultra-accurate TTL shooting is now available for continuous shooting based on electricity stored in a capacitor6. INON TTL Converter strives efficiency in battery consumption not to miss precious moment and successfully provides more than 100,000 flash triggering only by two CR2032 coin batteries.
* 4 shots/sec.in [Continuous shooting], 12 shots/sec. in [Continuous shooting +].Tested by INON with fully charged camera battery.
** Pause the strobe for a few minutes when taking more than 100 consecutive shots to avoid possible damage.
When strobe output gets extremely low such as using S-TTL, open aperture or high ISO sensitivity, the strobe can shoot continuously until the battery gets flat but the strobe may be damaged by the load.
Optionally available Quick Shoe System for quick camera position switching between landscape and portrait composition
Quick camera orientation change between landscape and portrait is available by attaching two optional "Quick Shoe W50 Plate" on the housing body and using "Quick Shoe Main Base" which adopts INON unique Arca Swiss system and two "D5 Holder" as handles.
In addition to vertical composition without changing lighting position, it also allows you to shoot vertical composition from low angle which is not possible with conventional system.
Built-in "Vacuum leak sensor" confirms housing sealing in 5 minutes
The "Vacuum Leak Sensor" ensures housing sealing by monitoring air pressure inside of the housing during leak check and warns accidental flooding with LED blinks and buzzer during diving. The onboard pressure sensor changes sensitivity for leak check and diving by variable control program (PAT. P).
The supersensitive pressure sensor detects even fine leakage. Not as like conventional leak sensors, it drastically shortens test time (from 30 seconds to 5 minutes). The sensitivity of the dive mode eliminates false alarm even when ambient temperature changes.
New S-MRS Port
Newly developed S-MRS (Magnetic Rotary System) controls focusing and zooming by magnetic attraction. The new S-MRS provides smoother operation with less play or rattle comparing to the previous model. By combining the EOS R6 Mark II with an RF lens, the MF Peaking function can also be used during full-time manual focusing. Together with the focus guide function, this enables ultra-precise focusing.
Maximum three MRS Control Rings can be installed to control the Control Ring, Focus Ring and SA Control Ring.
Optional two bright viewfinders
Optional viewfinders provide same magnification as camera’s viewfinder (1.0x) and extends its eye-point. Two options are available: “Straight Viewfinder Unit ll” or angled “45 degree viewfinder Unit III” * to choose depending on shooting conditions.
Lightweight and compact ultra-precision cast aluminum body
The X-2 R6 Mark II is made from corrosion resistance aluminum alloy by ultraprecise cast manufacturing technique to fuse design, weight and durability in higher dimension.
The cast manufacturing technique enables thin body plate with complicated curved design which is not possible with machining. Lightweight and durable aluminum alloy body has acquired reliability, durability and controllability even in severe underwater.
Compatible Camera
|
Canon EOS R6 Mark II
|
Compatible Strobe
|
INON
S-220/Z-330/D-200/S-2000/Z-240/D-2000 series |
Accessible Camera Controls
|
Shutter button
Main dial Quick control dial 1 Quick control dial 2 Mode dial Multi-controller Still photo shooting/movie recording switch <OFF/LOCK/ON>Power/multi-function lock switch <M-Fn> Multi-function button <MENU> Menu button <AF-ON> AF start button <INFO> Info button <RATE> Rating button Set button Movie shooting button Magnify/Reduce button Quick Control button AE lock button AF point selection button Playback button Erase button |
Lens Control
|
Controllable by S-MRS system on lens port
|
Optical Cable Connector
|
2
|
TTL converter
|
Specifically designed for EOS R5/R6/R6 Mark II. Operates on two CR2032.
|
Leak Sensor (buzzer/LED)
|
"Built-in switch for battery level and function check.
Operates on 1 x CR2032" |
Size (without Accessories)
|
W x H x D: 205 x 181 x 123mm/8.0 x 7.1 x 4.8 inch (body only)
|
Weight (air)
|
1,710 g/3.7 lb (body only)
|
Depth Rating
|
75 m/246 ft.
|
Operable Temp. Range
|
0 ℃-40 ℃/32 °F-104 °F
|
Material
|
Corrosion resistant aluminum alloy
|
Color
|
Teflon-molybdenum coating/charcoal gray
|
Accessories
|
Vacuum pump
INON Grease |